Altronix AL1002ULADA Installation Instructions Manual de usuario

Busca en linea o descarga Manual de usuario para Accesorios para eléctrica Altronix AL1002ULADA Installation Instructions. Altronix AL1002ULADA Installation Instructions User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Rev. 052313
AL1002ULADA
NAC Power Extender
Installation Guide
(See Application Guide for additional information)
Altronix Corp.
140 58th St. Brooklyn, NY
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - AL1002ULADA

Rev. 052313AL1002ULADANAC Power ExtenderInstallation Guide(See Application Guide for additional information)Altronix Corp.140 58th St. Brooklyn, NY

Pagina 2 - Specifications:

- 10 - AL1002ULADAAppendix A - UL Listed Compatible DevicesA.1 Four (4) Wire Smoke DetectorsTableA-1belowlistsfour(4)wiresmokedetectorscompat

Pagina 3 - Installation Instructions:

AL1002ULADA - 11 -A.1 Four (4) Wire Smoke Detectors (cont.)Smoke Detector/BaseDetector TypeMax StandbyCurrent (mA)AlarmCurrent (mA)SystemSensor4W-

Pagina 4 - (AL800LGK Board)

- 12 - AL1002ULADAEnclosure Dimensions (H x W x D approx.):15.5”x12”x4.5”(393.7mmx304.8mmx114.3mm)MEMBERAltronixisnotresponsibleforanyt

Pagina 5 - AL800LGK Logic Board

- 2 - AL1002ULADA Agency Listings:• ULListedControlUnitsforFireProtective SignalingSystems(UL864).• MEA-NYCDepartmentofBuilding

Pagina 6 - - 6 - AL1002ULADA

AL1002ULADA - 3 -Power Supply Specifications:AC Input:120VAC60Hz,5amp.Output:Four(4)regulatedsupervisedNACoutputcircuits,24VDC,2.5ampmax

Pagina 7 - AL1002ULADA - 7

- 4 - AL1002ULADA6. ConnectFACPoutputtodesiredAL800LGKlogicboardinputs,andnotificationappliancestodesiredAL800LGK  logicboardout

Pagina 8 - Maintenance:

AL1002ULADA - 5 -Amount of Notification Appliances per NAC:Amseco 27perNAC* SystemSensor® 32perNAC*Faraday 39perNAC* CooperWheelock® 32perN

Pagina 9 - Battery Calculation Worksheet

- 6 - AL1002ULADATerminal Identification Table:Power Supply Board*Terminal Legend Function/DescriptionL,N Connect120VACtotheseterminals:Ltoh

Pagina 10 - - 10 - AL1002ULADA

AL1002ULADA - 7 -ExternalJacketedShieldIncorrect WireHandlingCorrect WireHandlingPull backexternal jacketedshield approx. 1/2”.WireInsulationSolid Co

Pagina 11 - AL1002ULADA - 11

- 8 - AL1002ULADAOptional hookups:1- BatteryandACmonitoring:ACorBatteryFailconditionwillcausethecommontroubleinput[C“FAULT”NC]to

Pagina 12 - - 12 - AL1002ULADA

AL1002ULADA - 9 -Battery Calculation WorksheetDeviceNumber of DevicesCurrent per DeviceStand-by CurrentAlarm CurrentForeachdeviceusethis