Altronix NetWay112 Installation Instructions Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 4
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
- 4 - NetWay112
Altronix is not responsible for any typographical errors.
14058thStreet,Brooklyn,NewYork11220USA,718-567-8181,fax:718-567-9056
website:www.altronix.com,e-mail:[email protected],LifetimeWarranty,MadeinU.S.A.
IINetWay112 L07L
MEMBER
Maintenance:
Unitshouldbetestedatleastonceayearfortheproperoperationasfollows:
While the NetWay112 is powered and the output is connected to a suitable UL Listed PoE device.
The NetWay112 should be tested for PoE shutdown operation (For Information Technology applications only).
For Access Control applications, the NetWay1SP is to be tested as part of a complete Access Control System and in
accordance with listed Access Control Devices.
Troubleshooting:
Refer to NetWay112 Port Status and LED Flash Codes pg. 2.
Technical Specifications:
Parameter Description
No. of Ports One (1).
Input power requirements 12VDC@1.6amp.
Indicators Port Status LED.
PoE Shutdown Voltage
and Current Range
5VDC to 24VDC or 12VAC to 24VAC.
Maximumcurrent:2mAfor5VDC.
Maximumcurrentforhighervoltages:10mA.
Environmental Conditions OperatingAmbientTemperature: InformationTechnology-32ºFto104ºF(0ºCto40ºC).
AccessControl-32ºFto120.2ºF(0ºCto49ºC).
Relativehumidity:85%,+/---5%.
StorageTemperature:---4ºto158ºF(---20ºto70ºC)Storage.
OperatingAltitude:--- 1000 to 10,000 ft. (--- 304.8 to 3048m).
Regulatory Compliance
CE approved
Vista de pagina 3
1 2 3 4

Comentarios a estos manuales

Sin comentarios