Series
Access Power Controllers
Installation Guide
Models Include:
Rev. DCB102512
Maximal11D
- Power Supply 1:
12VDC @ 3.5 amp or 24VDC @ 2.7 amp.
- Power Supply 2:
12VDC @ 3.5 amp or 24VDC @ 2.7 amp.
- Sixteen (16) PTC protected
Class 2 Rated power-limited outputs.
Maximal33D
- Power Supply 1:
12VDC @ 5.5 amp or 24VDC @ 5.7 amp.
- Power Supply 2:
12VDC @ 5.5 amp or 24VDC @ 5.7 amp.
- Sixteen (16) PTC protected
Class 2 Rated power-limited outputs.
Maximal55D
- Power Supply 1: 12VDC @ 9.5 amp.
- Power Supply 2: 12VDC @ 9.5 amp.
- Sixteen (16) PTC protected
Class 2 Rated power-limited outputs.
Maximal77D
- Power Supply 1: 24VDC @ 9.7 amp.
- Power Supply 2: 24VDC @ 9.7 amp.
- Sixteen (16) PTC protected
Class 2 Rated power-limited outputs.
Maximal75D
- Power Supply 1: 12VDC @ 9.5 amp.
- Power Supply 2: 24VDC @ 9.7 amp.
- Sixteen (16) PTC protected
Class 2 Rated power-limited outputs.
More than just power.
TM
Altronix Corp.
140 58th St. Brooklyn, NY
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - Series

SeriesAccess Power ControllersInstallation GuideModels Include:Rev. DCB102512Maximal11D- Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp.-

Pagina 2 - Table of Contents:

- 10 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)+ DC --- BAT FAILNC C NO NC C NO+ BAT

Pagina 3 - MaximalD Series Overview:

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) - 11 - + DC --- BAT FAILNC C NO NC C NO– BAT

Pagina 4

- 12 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)+ DC --- BAT FAILNC C NO NC C NO– BAT

Pagina 5

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) - 13 - NEC Power-Limited Wiring Requirements for Maximal11D:P

Pagina 6 - Maintenance:

- 14 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)NEC Power-Limited Wiring Requirements for Maximal33D a

Pagina 7

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) - 15 - NEC Power-Limited Wiring Requirements for Maximal77D:P

Pagina 8

- 16 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)NEC Power-Limited Wiring Requirements for Maximal75D:P

Pagina 9 - Switch Detail

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) - 17 - ISOLATED POWER INPUT12 OR 24 VAC OR VDC(LOCK POWER) IS

Pagina 10 - Power Supply Board

- 18 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)Enclosure Dimensions (H x W x D) (approximate):26” (66

Pagina 11 - Fig. 4 - Maximal77D

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) - 19 - Notes:

Pagina 12 - Fig. 5 - Maximal75D

- 2 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)Table of Contents:MaximalD Series Overview ...

Pagina 13

- 20 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)Altronix is not responsible for any typographical erro

Pagina 14

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) - 3 - MaximalD Series Overview:Maximal Access Power/Controlle

Pagina 15

- 4 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)• RedLEDsonACM8CBboardindicateindividualoutputs

Pagina 16

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) - 5 - (a) Fail-Safe Switched Power outputs: For Fail-

Pagina 17 - OUTPUT EOL

- 6 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) supplies polarity must be observed. When using AC po

Pagina 18 - (H x W x D) (approximate):

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) - 7 - Power Supply Board Terminal Identification:Terminal Leg

Pagina 19

- 8 - Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC)Power Supply Board Stand-by Battery Specifications:Altr

Pagina 20

Maximal11D/Maximal33D/Maximal55D/Maximal77D/Maximal75D Access Power Controllers (PTC) - 9 - Power Supply Board Output Voltage Settings:Fig. 1 Fig.

Comentarios a estos manuales

Sin comentarios