- 4 - NetWay1
Altronix is not responsible for any typographical errors.
14058thStreet,Brooklyn,NewYork11220USA,718-567-8181,fax:718-567-9056
website:www.altronix.com,e-mail:[email protected],LifetimeWarranty,MadeinU.S.A.
IINetWay1 L12L
MEMBER
Maintenance:
Unitshouldbetestedatleastonceayearfortheproperoperationasfollows:
While the NetWay1 is powered and the output is connected to a suitable UL Listed PoE device.
The NetWay1 should be tested for PoE shutdown operation (For UL 60950-1 applications only).
For UL294 applications, the NetWay1 is to be tested as part of a complete Access Control System and in accordance
with listed Access Control Devices.
Troubleshooting:
Refer to NetWay1 Port Status and LED Flash Codes pg. 2.
Technical Specifications:
Parameter Description
No. of Ports One (1)
Input power requirements 24VAC@1.2amp(min.30VAtransformer,For UL 60950-1 applications only)
or24VDC@1.2amp.
Indicators Port Status LED
PoE Shutdown Voltage
and Current Range
5VDC to 24VDC or 12VAC to 24VAC
Maximumcurrent:2mAfor5VDC
Maximumcurrentforhighervoltages:10mA
Environmental Conditions OperatingAmbientTemperature: UL60950-1-32ºFto104ºF(0ºCto40ºC).
UL294-32ºFto120.2ºF(0ºCto49ºC).
Relativehumidity:85%,+/---5%
StorageTemperature:---4ºto158ºF(---20ºto70ºC)Storage
OperatingAltitude:--- 1000 to 10,000 ft. (--- 304.8 to 3048m).
Regulatory Compliance
UL/CUL Listed for Information Technology Equipment (UL 60950-1).
UL Listed for Access Control Systems (UL294).
Power over Ethernet (PoE) for Access Control (UL294B).
CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment.
CE approved