- 2 - HubWayEXP UTP Power Injector
Overview:
Altronix HubWayEXP UTP Power Injector supplies power combined with pass through video and data for up to 16 cam-
eras from Altronix HubWay Active UTP Transceiver Hubs. Unit allows for video transmission of up to 16 cameras over
four CAT-5 or higher structured cables from HubWay Active Transceiver Hubs. The HubWayEXP units are designed for
installation at the IDF (Intermediate Distribution Frame) or MDF (Main Distribution Frame).
Specifica tions:
Input:
• 115VAC 60Hz, 2.5 amp or 230VAC 50Hz, 1.5 amp.
Power:
• Unitprovidesupto1ampmax.perchannelnotto
exceed a total of 16 amp maximum current.
• Individuallyselectable24VACor28VACpoweroutputs
with OFF position.
• IndividualelectronicallyisolatedPTCoutputs.
• PTCsarerated@1ampperchannel.
• Surgesuppression.
Visual Indicators:
•IndividualpowerLEDindicators.
Features:
• Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset.
• IEC320-3-wirereceptacle.
• Unitcanberack,wallorshelfmounted.
• 1UrackmountchassisforuseinstandardEIA19”rack.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This
installation should be made by qualified service personnel and should conform to all local codes.
Installation Instructions:
WiringmethodsshallbeinaccordancewiththeNationalElectricalCode/NFPA70/ANSI,andwithalllocalcodesand
authorities having jurisdiction. Wiring should be ULListedand/orRecognizedwiresuitablefortheapplication.
1. AttachmountingbracketstoHubWayEXPunitforrackorwallmountinstallation(Figs. 7-8, pg. 8). Affix rubber
pads to HubWayEXP for shelf installation (Fig. 9, pg. 8).
2. Securetheunitinarack,mountunittoawallorplaceunitonashelfasdesired(unitshouldbespacedatleast
3”fromanyvideomonitors).
3. Setilluminatedmasterpowerdisconnectcircuitbreakertothe(OFF)position(Fig. 6, pg. 7).
4. PlugthegroundedAClinecordintotheIEC320connectoroftheHubWayEXP.ForUS&Canadatheplugendisa
3 prong type B plug used for standard 115VAC receptacles, as provided with unit (Fig. 1f, pg. 4). For non North
American 230VAC applications use the appropriate 3 prong plug that matches the local standard receptacle.
5. Setvoltageoutputselectorswitchofeachcamerachannelfor24VACor28VAC(Fig. 3c, pg. 4).
6. For video transmission:
a. HubWayEXPinterfacetoHubWayEX16Sunit-ConnectaCAT-5cabletotheRJ45jackmarked[CH1-4,
 CH5-8,CH9-12,CH13-16](Fig. 3d, pg. 4). Connect the opposite end of this CAT-5 cable into the
 correspondingRJ45jackmarked[CH1-4,CH5-8,CH9-12,CH13-16]ofHubWayEX16S(Fig. 4, pg. 5).
b. HubWayEXPinterfacetoHubWayEX16orHubWayEX32unit-ConnectaCAT-5cabletotheRJ45jack
 marked[CH1-4,CH5-8,CH9-12,CH13-16](Fig. 3d, pg. 4). Connect the opposite end of this CAT-5 cable
 intothecorrespondingRJ45jackmarked[CH1-4,CH5-8,CH9-12,CH13-16]ofHubWayEX16or
HubWayEX32 unit (Fig. 5, pg. 6).
7. For data (PTZ) connections (When using fixed cameras disregard this step):
a. HubWayEXPinterfacetoHubWayEX16Sunit-ConnectanadditionalCAT-5cabletotheRJ45jackmarked
 [DATA]ontherearofHubWayEXP (Fig. 3e, pg. 4). Connect the opposite end of this CAT-5 cable into any
 unusedRJ45jackmarked[1-16]ofHubWayEX16Sunit(Fig. 4, pg. 6).
b. HubWayEXP interface to HubWayEX16 or HubWayEX32 unit - Connect an additional CAT-5 cable to the
 RJ45jackmarked[DATA]ontherearofHubWayEXP (Fig. 3e, pg. 4). Connect the opposite end of this CAT-5
cableintotheRJ45jackmarked[DATA]ofHubWayEX16orHubWayEX32unit (Fig. 5, pg. 6)
8. ConnectaCAT-5cabletotheRJ45jackmarked[1](Fig. 3a, pg. 4). Connect the opposite end of this CAT-5 cable
into the Video Balun/Combiner to be installed at camera 1 (repeat this step for cameras 2-16).
• For24VACcamerasuseAltronixmodelHubWayAvVideoBalun/Combiner(Figs. 1a, 1b, pg. 3).
• For12VDCcamerasuseAltronixmodelHubWayDvVideoBalun/Combiner(Figs. 1c, 1d, pg. 3).
The total cable distance must not exceed 5000 ft. for video transmission between the HubWayEXP and
HubWayEX16S,HubWayEX16ORHubWayEX32andeachcamera.
9. SetilluminatedmasterpowerdisconnectcircuitbreakertotheRESET(ON)position(Fig. 6, pg. 7) power
LEDs(Green)oftheHubWayEXP will illuminate when AC power is present (Fig. 3b, pg. 4) and HubWayAv or
Vista de pagina 1