
- 4 - HubWayEXP UTP Power Injector
AC POWER
1234
CH 1-4 CH 5-8
28VAC
OFF
24VAC
5678 9101112
CH 9-12 CH 13-16
13 14 15 16
28VAC
OFF
24VAC
OFF
RESET
+ DATA - -
1-8
+ DATA - -
9-16
3a - Port(s) 1-16:
CAT-5 or higher
structured cable to
cameras 1-16.
3c - Output voltage switch-
es: Selects24VAC/28VAC/
OFF for each output.
3d - Video 1-4: SingleCAT-5
or higher structured cable out
to HubWayEX16/EX32 or
HubWayEX16Senables
transmissionofuptofour(4)
video signals.
3f - IEC 320 Connector:
Groundedlinecordincluded.
Fig. 3
3e - Data: Removableterminalblocks
forRS422/RS485inputfromheadend
equipment(DVR)forPTZcontrol.
3b - LED(s) 1-16:
Power indicators.
Front
Rear
Comentarios a estos manuales